01

First separate loaded interference from shell geometry

Close the empty shell on a flat surface, then add the insert, product and card one at a time. Note when the lid changes position. A tall pump, raised insert edge or folded leaflet can touch the lid before the closure faces meet. If the empty shell also sits unevenly, inspect hinge movement, panel shape and the wrapped edges. Do not press a sample flat and treat that as approval.

The skincare book-style box shows a hinged presentation layout. It is a design reference, not evidence that any other product fits or that its closure has been tested.

02

Read the symptom without assuming a single cause

What to compare on the finished sample
ObservationInvestigateNext comparison
Only loaded box liftsProduct or insert contact with lidAdd components one at a time
One corner lifts when emptyHinge, panel, wrap or closure positionCompare a second finished sample
Lid shifts sidewaysClosure alignment and hinge positionMark positions on approved drawing
Closure weak through finishMagnet pairing, intervening layers and geometryCompare complete finished constructions

These are investigation routes, not proof of a root cause. Humidity, materials and production variation also need project-specific review.

03

Why the finished material stack matters

Magnet performance depends on the actual pairing and separation. The magnet supplier Supermagnete explains that attractive force drops as separation increases and that surface conditions matter.[1] In a wrapped box, the board recess, cover, lining and alignment all form part of the finished construction to review. Its published measurements are not specifications or test results for an MTT box.

Ask the converter to identify the closure arrangement and drawing revision. Compare alternatives on finished samples with the same wrap, insert and contents; a stronger magnet can change opening feel and does not fix a product physically pushing the lid away.

04

Make acceptance observable

Agree which orientation, contents and surface are used when checking closure. Record edge alignment, visible lifting, opening and closing feel, and any movement after normal handling. Ask the responsible parties to define a project-specific method and acceptance range; there is no universal lid gap or magnet force stated here. Compare several representative samples where feasible and keep any measurements with their sample IDs.

Illustrative example: if an empty sample closes normally but lifts only when a serum with its dropper is installed, measure the complete closed product and lid clearance before changing the magnets. This is an engineering example, not a reported customer defect.

05

Confirm the complete delivery scope

Provide the filled products, artwork and insert revision, quantity per design and destination. Ask what is included in shell, insert, magnet, sampling and tooling charges. If the box will be shipped as a filled set, agree the outer packaging and distribution test separately: a magnetic snap is not a shipping certification. See the book-style construction guide and change and retest checklist.

06

Sources

  1. Supermagnete: factors affecting magnetic holding force, accessed 16 November 2026.